0.06m3 per hour, while the largest XLG-65 can test the flow of 100m3 per hour, What’s more, even the largest XLG-65 is only 170mm × 290mm × 155mm in size and 3kg in weight. You can easily install our products.
Moreover, our product consumes the input power of 3.6V, the allowable voltage fluctuation is between 2.5 to 5.5V. The Li-battery can support the meter for 8 years. The stable current is 30uA while the working current is 4-20mA.The LCD will flicker when the voltage is lower than 2.5V.
In addition, our product has passed ExibIIBT3 class anti-explosion test GB3836.4 in national authorized anti-explosion facility. The operation temperature could be from -30℃ to 60℃ and the relative humidity from 20% to 85%. In these conditions, our product could have an accuracy of ±1.5%.
Technical Specification Model | XIG-10 1” | XIG-16 1” | XIG-25 1.5” | XIG40 2” | XIG-65 2’ |
Normal(m3/h ) | 10 | 16 | 25 | 40 | 65 |
Min.(m3/h ) | 0.06 | 0.16 | 0.25 | 0.40 | 0.65 |
Max.(m3/h ) | 16 | 25 | 40 | 65 | 100 |
Max.Pressure (MPa ) | 0.2 |
Pressure loss (Pa ) | 200 | 300 |
Accuracy | | | 1.5% | | |
Measure Accuracy | Qmin≤Q<0.1Qmax: ±3 ﹪ |
0.1QMax≤Q≤Qmax: ±1.5 ﹪ |
Temperature ( ℃ ) : | -30~ 60 | | | | |
Resolution ( L ) | 0.1 | | | | |
Max (m3 ) | 999999.9999 |
Suitable for: | gas 、 natural gas 、 LPG 、 Oxygen etc |
Output option: | 4-20mA or Pulse output |
Connection: | Thread connection |
NW(Kg ) | 1.5 | 1.5 | 2.0 | 3.0 | 3.0 |
A ( mm ) | 145 | 145 | 160 | 170 | 170 |
B ( mm ) | 240 | 240 | 270 | 290 | 290 |
C ( mm ) | 123 | 123 | 156 | 155 | 155 |
R | R1 | R1 | R11/2 | R2 | R2 |