Home Solar Charger Inverter

Solar Charger Inverter

Features
Advanced MPPT technology with an efficiency of 99.9% topology, to maximize battery performance
Multiple working modes are optional for different working priority (Grid / battery / energy saving mode)
Electricity bypasses quick charging function
Solar panel MPPT Charging technology
User-friendly multiple communication modules (RS485, RS232, -CAN, GPRS, WIFI) are optional to be compatible with more monitoring device: mobile, computer, Internet/remote operation
Over-load and short-circuit protection.
Capable of providing the continuous power to linear load or not-liner load of lamp, computer, fridge, air-conditioner, fans, and household appliances and industrial power Application Examples Communications base station Nomadic area Farm How it works?
Technical Parameters
Rated output voltage RF4830S60-H RF4850S80-H
Line mode
AC input voltage 220/230V AC
AC input voltage range (170Vac~280Vac) ±2%;(90Vac-280Vac)±2%
Rated frequency 50HZ/ 60Hz ( auto detection)
Frequency range 47±0.3Hz ~ 55±0.3Hz for 50Hz; ( 57±0.3Hz ~ 65±0.3Hz for 60Hz)
Over-load/short-circuit protection Circuit breaker
Efficiency >95%
Transfer time (AC to DC or DC to AC): 10ms ( typical )
Bypass relay current 30A 40A
Invert mode
Output voltage waveform Sine wave
Rated output power 3000VA/3000W 5000VA/5000W
Power factor 1
Rated output voltage 220/230(±5%)Vac
Rated output frequency 50Hz ±0.3Hz/60Hz ± 0.3Hz
Efficiency >92%
Over-load protection 102%0% ±10%: fault(shutdown output)after 50S
Peak power (10s) 6000VA 10000VA
Capable of starting electric motor 2HP 4HP
Output short-circuit protection Circuit breaker
Output breaker current 30A 40A
DC input voltage/ Min. DC start voltage 48VDC (minimum starting voltage 44V)
Battery voltage range 40VDC~60Vdc ± 0.6Vdc
Power saving mode Load≤25w
Charge(line)
Battery type lead acid or lithium battery
Charge current 60A
Charge current regulation ± 5Adc
Battery voltage range 40-58Vdc
Charge short-circuit protection circuit breaker and blown fuse
Breaker current 40A
Over charge protection alarm and turn off charging after 1minute
Charge(solar)
MPPT voltage range 60-115Vdc
Max. PV input voltage 145Vdc
Max. PV open circuit voltage 145Vdc
Battery voltage range 40V-60Vdc
Max. output power 3200W 4200W
PV charging current range 0-60A 0-80A
Battery short-circuit protection Blown Fuse
Wiring protection Anti-reverse connecting protection
Others
Dimension (L*W*D) 430X338X126mm
Weight 10kg
Degree of protection IP20(force air,variable speed fan)
Operation temperature range -15~ 40ºC (-25ºC ~ 60ºC for storage )
Relative humidity 5%~95%
Communication interface RS-485/GPRS/WiFi
Safe certificate/ EMC certificates CE(EN62040-1, EN62040-2)/ C2