Home Flame Retardant Mine Cable

Flame Retardant Mine Cable

FlameRetardant Mine Cable

Mine cable, known as coal mineused cable, it is referred to as those electric wires for coal mining plantssuch as coal cutter, coal preparation plant, lighting equipment, signaling equipment,electric drill, cap-lamp, etc. We are able tomanufacture a wide range of flame retardant mine cables. The following typesare available: M, MCP, MZ, MZP, MYP, MCPTJ, MYPJ, MVV, MKVV, MYJV, MKYJV, MHYVand UGF. We can supply high voltage mine cable, 10kV rubber cable, 6kV minecable, mobile crane cable, mining flame retardant cable, etc. Our flameretardant mine cables are all manufactured in strict accordance with theMT818-1999 standard.

Cable Type

Model

Name

MY

Moveable rubber jacketed flexible mine cable

MYQ

Moveable rubber jacketed flexible mine cable, light type

MYP

Moveable shield rubber jacketed flexible mine cable

MC

Rubber jacketed flexible cable for coal cutter

MCP

Shielded rubber jacketed flexible cable for coal cutter

MZ

Rubber jacketed flexible cable for mining electric drill

MZP

Shielded rubber jacketed cable for mining electric drill



Operating characteristics
1.
Ratedpower-frequency voltage U0/U (Um): 380/66V, 660/1140V
2. Themaximum operating temperature of conductor is 65℃.
3. Our flame retardant mine cable operates with an ambient temperature no lessthan -35℃.
4. The bend radius is no less than 6 times the cable outer diameter.
 


 Technical Data


Model

Core number

Rated voltage (kV)

Nominal cross-section area (mm2)

Power wire core

Ground wire core

Control wire core

MY

1

0.38/0.66

50-150

-

-

3 1

3×4-3×70

1×4-1×25

-

MZ MZP

3 1、3 1 1

0.3/0.5

3×2.5-3×4

1×2.5-1×4

1×2.5-1×4

MYQ

2、3、4、

7、12

0.3/0.5

1.0-2.5

-

-

3 1

3×1.0-3×2.5

1×0.75-1×1.5

MC

3 1 3

0.38/0.66

3×16-3×50

1×4-1×10

3×2.5-3×4

MCP

3 1 3

0.38/0.66

3×16-3×50

1×4-1×10

3×2.5-3×4

0.66/1.14

3×35-3×95

1×6-1×25

MYP

3 1

0.38/0.66

3×4-3×70

1×4-1×25

-

0.66/1.14

3x10-3x95

1×10-1×25


 



1、Power wire core conductorand conductor shield


2、Rubber insulation


3、Insulating shield, alsofunctioned as the ground wire


4、Inside sheath


5、Monitor wire core andsemiconductor strips coating layer


6、Outer sheath



Power wire core conductor

2、Ground wire core conductor


3、Control wire core conductor


4、Insulating layer


5、Insulating shield


6、Over sheath


 



1、Power wire core conductor


2、Ground wire core conductor


3、Insulating layer


4、Metal/fiber shield


5、Monitor wire core conductor


6、Monitor wire core


7、Over sheath

Technical Feature
The main technical features are shown in the following tables:

DC resistance of the cable conductor


Model

Nominal cross-section area(mm2)

DC resistance at 20℃

(≤Ω/Km)

Model

Nominal cross-section area(mm2)

DC resistance at 20℃

(≤Ω/Km)

Non-tinplating

Tinplating

Non-tinplating

Tinplating

MYQ

1.0

19.5

20.0

MY MYP

10

1.91

1.95

1.5

13.3

13.7

16

1.21

1.24

2.5

7.98

8.21

25

0.780

0.795

MZ MZP

2.5

-

8.82

35

0.554

0.565

4

-

5.39

50

0.386

0.393

MC MCP

4

-

5.09

70

0.272

0.277

6

-

3.39

95

0.206

0.210

10

-

1.95

120

0.161

0.164

16

-

1.24

150

0.129

0.132

25

-

0.795

185

0.106

0.108

35

-

0.565

240

0.0801

0.0817

50

-

0.393

300

0.0641

0.0654

MY MYP

4

4.95

5.09

400

0.0485

0.0495

6

3.30

3.39

-

-

-


 
Insulating Resistance of Cable


Model

Power wire core

Nominal cross-section area(mm2)

Insulating resistance at 20℃ (≥MΩ Km)

Model

Power wire core

Nominal cross-section area(mm2)

Insulating resistance at 20℃ (≥MΩ Km)

MYQ

1.0

160

MY

MYP

10

160

1.5

160

16

120

2.5

160

25

120

MZ MZP

2.5

160

35

100

4

160

50

100

MC MCP

16

120

70

80

25

120

95

80

35

100

120

50

50

100

150

50

70

80

185

50

95

80

240

50

Monitor wire core

100

300

50

MY MYP

4

200

400

50

6

180

-

-



Power Frequency Voltage Test (for 5min)


0.66/1.14

Insulation not breakdown at 3.7kV PF voltage

0.38/0.66

Insulation not breakdown at 3kV PF voltage

0.3/0.5

Insulation not breakdown at 2kV PF voltage

Control wire core

Insulation not breakdown at 1.5kV PF voltage



Flame Test for Bunched Cables
Type A flame test is performed for cables withmaximum section areas more than 50mm2 and type B test is performed for those with maximum section areas less than 50mm2.

Application


Model

Specification range

Application

MYQ MYQE

1.0-25mm2 2-12 cores

It is suitable for underground lighting equipment, conveyor, signaling and control equipment with rated voltage up to 0.66/1.14kV.

U UP

3 1cores,3 2cores 1.5-6mm2

It is suitable for underground equipment with rated voltage up to 0.66/1.14kV

3 1cores,10-95mm2

UC(MC)

UCP(MCP)

3 1cores 3 1 (1 – 7)cores 10-95mm2

For all kinds of underground moveable coal cutters and road headers at rated voltage 0.38/0.66kV or 0.66/1.14kV



Huanya is a professionalflame retardant mine cable manufacturer and supplier in China. For over 2 decades, westrived to develop and manufacture high quality powercables include computer cable, hightemperature resistant cable, rubber sheath insulatedcable and welding machine cable, etc. If you are in need of our product,please do not hesitate to contact us. Welcom!

Flame Retardant Mine Cable

 


Recommended Products
Hot Products