Description
Model | Dimension (mm) L×B×H | Net Weight (kg) | Instruction |
400GF1-RT | 5251×1970×2235 | 10090 | This is a common type of natural gas generator set designed with open cooling method foe heat exchanger. |
400GF1-PwT | 5251×1970×2235 | 9690 | This is a common type of natural gas generator set designed with the closed cooling method for horizontal water box with more than one fan. |
400GF1-PT | 5680×1970×2556 | 10870 | This is a common type of natural gas generator set designed with closed cooling method for vertical water box with fan. |
400GFZ1-RT | 5251×1970×2235 | 10090 | This is an automatic type of natural gas generator set designed with ESM3 control system and open cooling method for heat exchanger. |
400GFZ1-PwT | 5251×1970×2235 | 9690 | This is an automatic type of natural gas generator set designed with ESM3 control system and closed cooling method for horizontal water box with more than one fan. |
400GFZ1-PT | 5680×1970×2556 | 10870 | This is an automatic type of natural gas generator set designed with ESM3 control system and closed cooling method for vertical water box with fan. |
Conditions for Using
1. For pressurized natural gas generator in this natural gas generator set, the pressure for air inflow is 100kPa~300kPa; for unpressurized natural gas generator, the pressure for air inflow is 30kPa~300kPa.
2. If the distance between the natural gas and the pressure regulating valve for air inflow is 1m or nearer, the temperature of the natural gas should not surpass 40℃.
3. The content of the methane in natural gas for this natural gas generator set should not be lower than 70% and the low heating value is 32MJ/Nm3~45MJ/Nm3.
4. The content of H2S should not surpass 20mg/Nm3 and the total content of sulfur should not surpass 480mg/Nm3.
5. The granularity of the impurity should not surpass 5μm and the content of the impurity should not surpass 30mg/Nm3. There should not be any free water, clean oil, etc.
Technologies Used
Technologies that this natural gas generator set uses include electrical fuel gas mixing technology, low-pressure air inflow technology, automatic control technology for burning and safe conveying system.
Technical Parameters
Name of Parameter | Value of Parameter | |
Model of the set | 400GF1-RT/PwT/PT | 400GFZ1-RT/PwT/PT |
Model of gas engine | T12V190-2A | |
Model of generator | 1FC6 408-6LA42 | |
Rated power(kW) | 400 | |
Rated current(A) | 722 | |
Rated voltage(V) | 400 | |
Rated frequency(Hz) | 50 | |
Rated rotated speed(r/min) | 1000 | |
Rated power factor(cosφ) | 0.8(lag) | |
The number of phase and the wiring method | Three coils wired by three phase lines or three coils wired by three phase lines and one zero line. | |
Way for adjusting pressure | Automatic adjusting pressure | |
Excitation method | Brushless excitation | |
Starting up method | 24VDC Electric starting system |
Technical Parameters
Name of Parameter | Value of Parameter |
Model | T12V190-2A |
Number of cylinder | 12 |
Arranging way of cylinders | V shape with the included degree of 60° |
Diameter of cylinder(mm) | 190 |
Route(mm) | 210 |
Total displacement(L) | 71.45 |
Air inflow way | Naturally aspirated |
Rated power(kW) | 450 |
Rated rotate speed(r/min) | 1000 |
Min. stable rotate speed with empty load(r/min) | 600 |
Dimension(L×B×H) (mm) | 2400×1560×2070 |
Net weight(kg) | 5640 |