We offer clients 3 types of battery dry chambers; please contact us for more specific information.
Model | ZKCO-2F-3D |
Internal Dimension | 3×260(H)×800(W)×600(D)mm |
External Dimension | 1800(H)×1350(W)×1080(D)mm |
Principle | Adopts special purpose detector: vacuum degree (-95KPA) or Nitrogen (-18KPA), the output signal is sent to PLC which can finish: vacuum supply-nitrogen filling-vacuum supply-nitrogen filling (recycling) |
Main Parameters | 1: Independent temperature control for 3 chambers. |
2: Temperature range: room temperature~150℃ | |
3: Vacuum degree: -0.095~-0.1Mpa | |
4: Temperature uniformity: ±3%℃ | |
5: Side wall temperature: ﹤35℃ | |
6: Independent large flow rate hot air circulation for 3 chambers | |
7: Power: three-phase five wire system, AC 380V | |
8: Maximum power consumption: 18KWA | |
9: Effective dimension of each chamber: H330mm×W800mm×D600mm | |
10: Net weight: 730KG | |
11: Heat-up time: About 30 minutes from room temperature ~90 ºC. Heating tube power: 5KW (each layer) | |
12: Heating method: internal heating | |
Model | ZKCO-3F-3D |
Internal Dimension | 3×330(H)×800(W)×800(D)mm |
External Dimension | 1980(H)×1350(W)×1380(D)mm |
Principle | Adopts special purpose detector: vacuum degree (-95KPA) or Nitrogen (-18KPA), the output signal is sent to PLC which can finish: vacuum supply-nitrogen filling-vacuum supply-nitrogen filling (recycling). |
Main Parameters | 1: Independent temperature control for 3 chambers. |
2: Temperature range: room temperature~150℃ | |
3: Vacuum degree: -0.095~-0.1Mpa | |
4: Temperature uniformity: ±3%℃ | |
5: Side wall temperature: ﹤35℃ | |
6: Independent large flow rate hot air circulation for 3 chambers | |
7: Power: three-phase five wire system, AC 380V | |
8: Maximum power consumption: 18KWA | |
9: Effective dimension of each chamber: H330mm×W800mm×D600mm | |
10: Net weight: 730KG | |
11: Heat-up time: About 30 minutes from room temperature ~90 ºC. Heating tube power: 5KW (each layer) | |
12: Heating method: internal heating | |
Model | ZKCO-7F |
Internal Dimension | W800mm×D900mm×H1500mm |
External Dimension | W1250mm×D1400mm×H2275mm |
Principle | Be able to achieve: vacuum supply -nitrogen filling-heating-heat preservation-pressure maintaining and drying- vacuum supply (automatic recycling control). Be beneficial for discharging moisture and preventing oxidation. Manual control and automatic control are optional. |
Main Parameters | 1: Room temperature-150℃ |
2: Full load test, it takes less than 30 minutes from starting heating to finish baking. | |
3: Header Control Precision: ±1℃ | |
4: Temperature Uniformity: ±2℃ (full load test) | |
5: Cooling Rate: It takes less than 1 hour from 90℃ to below 40℃. | |
6: Adopts single wall and integrated pump box design, the control box is located on the right side. And blanking plate is equipped. | |
7: Vacuum Degree: ≤133Pa | |