Description
Duct laying fiber optic cables are a common communication fiber optic cable used primarily in outdoor applications. We provide GYXTW duct fiber optic cables to our customers, and the production process is as follows. We first insert the 250um optic fiber into a loose tube made of a high modulus material and then fill the loose tube with a waterproof compound. The loose tube is then wrapped with PSP, and a water blocking material is inserted between the loose tube and PSP in order to ensure the tube is tightly coated and waterproof. Finally, two steel wires are placed parallel to each side of the PSP jacket, then squeezed in a PE sheath.
Standard
Technical ParametersType (increase by two fibers ++) | Fiber count | Cable diameter (mm) | Cable weight (kg/km) | Allowable tensile strength (short/long term) (N) | Allowable crush resistance short/long term (N/100mm) | Bend radius dynamic/ static (mm) |
GYXTW 2-12 | 2-12 | 8.9 | 100 | 600/1500 | 300/1000 | 10D/20D |
GYFTA 8-12 | 8-12 | 10.6 | 124 | 1000/3000 | 1000/3000 | 10D/20D |
GYFTA 14-18 | 14-18 | 12.0 | 147 | 1000/3000 | 1000/3000 | 10D/20D |
GYFTA 20-24 | 20-24 | 12.0 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
GYFTA 26-30 | 26-30 | 15.0 | 207 | 1000/3000 | 1000/3000 | 10D/20D |
Storage/Operating Temperature: -40℃ to +70℃ |
G652 | G655 | 50/125UM | 62.5/125UM | ||
Attenuation (+20℃) | @850nm | ≤0.30db/km | ≤3.3db/km | ||
@1300nm | ≤1.0db/km | ≤1.0db/km | |||
@1310nm | ≤0.36db/km | ≤0.40db/km | |||
@1550nm | ≤0.22db/km | ≤0.23db/km | |||
Bandwidth (grade A) | @850 | ≥500MHz.km | ≥200MHz.km | ||
@1300 | ≥1000MHz.km | ≥600MHz.km | |||
Numerical aperture | 0.200±0.015NA | 0.275±0.015NA | |||
Cutoff wavelength of optic fiber | ≤1450nm | ||||
Application: duct fiber optic cable |