The inverter charger offers a hybrid system that combines solar energy and commercial power while providing users with the flexibility of choosing the form of energy according to their needs. It features mains/diesel and solar charging, mains bypass and inverter output, and energy management and control, allowing users to maximize their use of solar energy while supplementing with commercial power if needed. This product ensures a reliable and secure power supply with its high-quality, high-stability, and high-reliability outputs, making it ideal for use in solar energy and commercial power/diesel generator hybrid power generation systems.
Features Two operating modes: battery-powered mode and non-battery powered mode.Model | UP2000-HM6022 | UP3000-HM10022 | UP3000-HM5042 | UP5000-HM8042 | |
Rated battery voltage | 24VDC | 48VDC | |||
Battery input voltage | 21.6~32VDC | 43.2~64VDC | |||
Max. battery charge current | 60A | 100A | 50A | 80A | |
Inverter Output | |||||
Continuous output power | 2000W | 3000W | 3000W | 5000W | |
Max. surge power (3s) | 4000W | 6000W | 6000W | 8000W | |
Output voltage | 220VAC(-6%~ 3%), 230VAC(-10%~ 3%) | ||||
Output frequency | 50/60±0.2% | ||||
Output waveform | Pure sine wave | ||||
Load power factor | 0.2-1 (load power ≤ continuous output power) | ||||
Total harmonics distortion (THD) | THD≤3% (resistive load) | ||||
80% rated output efficiency | 92% | 92% | 92% | 92% | |
Max. rated output efficiency | 91% | 91% | 90% | 91% | |
Max. output efficiency | 93% | 93% | 93% | 93% | |
Switch time | 10ms (switch from the utility output to the inverter output) 15ms (switch from the inverter output to the utility output) | ||||
Utility Charging | |||||
Utility input voltage | 176VAC~264VAC(default), 90VAC~280VAC (programmable) | ||||
Utility input frequency | 40~65Hz | ||||
Max. utility charge current | 60A(when the utility input voltage is 90VAC~180VAC, the max. utility charge current is 30A) | 80A(when the utility input voltage is 90VAC~180VAC, the max. utility charge current is 40A) | 40A(when the utility input voltage is 90VAC~180VAC, the max. utility charge current is 20A) | 60A(when the utility input voltage is 90VAC~180VAC, the max. utility charge current is 30A) | |
Solar Charging | |||||
Max. PV open circuit voltage | 450V (at minimum environment temperature) 395V (25℃ environment temperature) | 500V (at minimum environment temperature) 440V (25℃ environment temperature) | |||
MPPT voltage range | 80~350V | 120~400V | |||
Max. PV input power | 2500W | 4000W | 4000W | 4000W | |
Max. PV charge power | 1725W | 2875W | 2875W | 4000W | |
Max. PV charge current | 60A | 100A | 50A | 80A | |
Equalization voltage | 29.2V (default AGM battery type) | 58.4V (default AGM battery type) | |||
Boost voltage | 28.8V (default AGM battery type) | 57.6V (default AGM battery type) | |||
Float voltage | 27.6V (default AGM battery type) | 55.2V (default AGM battery type) | |||
Low voltage disconnect voltage | 21.6V (default AGM battery type) | 43.2V (default AGM battery type) | |||
Tracking efficiency | ≥99.5% | ||||
Temperature compensate coefficient | -3mV/℃/2V (default) | ||||
General | |||||
Surge current | 50A | 60A | 56A | 95A | |
No-load consumption | < 1.8A | < 1.2A | |||
Standby current | < 1.2A | < 0.7A | |||
Mechanical Parameters | |||||
Dimensions (H×W×D) | 607.5×381.6×127mm | 642.5×381.6×149mm | 607.5×381.6×149mm | 642.5×381.6×149mm | |
Mounting size | 585×300mm | 620×300mm | 585×300mm | 620×300mm | |
Mounting hole size | Ø10mm | Ø10mm | Ø10mm | Ø10mm | |
Net weight | 15kg | 19kg | 18kg | 19kg | |
Enclosure | IP30 | ||||
Environment temperature | -20℃~50℃ |