Davit arm electric door opening Side pneumatic door opening
Features The circulating fans can homogeneously heat the glasses inside the furnace via air convection in the circulation cycles.
External air and water supply system are controlled by the PLC system and proportional valve which can precisely adjust the air and water supply depending on the amount and thickness of glass, pressure level and temperature curve.
Autoclave door is controlled by the pneumatic valve and the air supply/exhaust system is automatically adjusted by the PLC system.
One button start-up delivers the simplest operations.
Choose Your Model Model | | | | | | | | | |
Inner diameter (mm) | 2500 | 2700 | 2700 | 2850 | 2850 | 3200 | 3200 | 3500 | 3500 |
Length (mm) | 6000 | 6000 | 8000 | 6000 | 8000 | 6000 | 8000 | 12000 | 15000 |
Design pressure (Mpa) | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
Design temperature (°C) | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
Working pressure (Mpa) | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 |
Working temperature (°C) | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 |
Working medium | Air | Air | Air | Air | Air | Air | Air | Air | Air |
Rail distance in autoclave (mm) | 850 | 850 | 850 | 850 | 850 | 1000 | 1000 | 1000 | 1000 |
Heating capacity (kW) | 135 | 162 | 198 | 189 | 225 | 225 | 270 | 324 | 378 |
Total motor power | 18.5 | 18.5 | 22 | 22 | 22 | 22 | 30 | 30 | 37 |