The wall mounted UV air disinfection system is an indirect air disinfector that is based on UV light and air recirculation. It uses UV light to effectively deactivate airborne bacteria and viruses to prevent the spread of disease and improve air quality, thereby offering a hygiene environment for medical personnel and patients.
Technology
The unique disinfection cavity makes it possible to implement continuous air disinfection in the presence of people, and the built-in air filtration system makes use of physical filtration and laminar flow technology to remove dust and bacteria in the air.
Feature
1. This indoor air disinfection unit doesn’t generate peculiar smell or radiation when working, and the machine body won’t get corroded.
2. Our UV air disinfection system is outfitted with several components to realize different functions. For example, the durable UV lamp gives out high intensity UV light to kill microorganisms, the negative ion generator creates negative ions to refresh air, while photocatalyst and activated carbon are combined together to removal odor.
3. This UV air purifier is operated automatically by a microcomputer, and it can be turned on or shut down at a predetermined time. Moreover, an infrared controller and a digital display panel are both adopted to achieve convenient manipulation.
4. When it comes to air recirculation, the wind speed and wind direction can be adjusted as well. This UV air disinfection system is able to check if the lamp fails to work.
5. High quality ballasts are optional, and they have anti-interference metal enclosure to ensure stable and reliable performance. In addition, cross-flow fan is equipped.
Application Range
1. Hospital: Operating room, supply room, medication room, patient room, treatment room, rest room, etc.
2. Blood station: Blood taking room, bioclean room, blood bank, etc.
3. Food and beverage plant: Manufacturing workshop, warehouse, buffer room, changing room, laboratory, etc.
4. Pharmaceutical factory: Sterile workshop, warehouse, buffer room, changing room, laboratory, etc.
5. Livestock breeding plant: Poultry farming room, sterile inoculation room, etc.
Model | Air flow | Room volume | Input power | HEPA | Programme control | Remote control | Installation size |
KT | ≥600m3/h | ≤60m3 | ≤180W | Yes | Yes | Yes | 27×20×80cm |
KT-B80 | ≥900m3/h | ≤80m3 | ≤200W | Yes | Yes | Yes | 32×20×98cm |
KT-B100 | ≥1000m3/h | ≤100m3 | ≤250W | Yes | Yes | Yes | 32×23×107cm |
Disinfection effect | ≤200 cfu/m3 | ||||||
Outer UV leakage | ≤0 μW/cm3 | ||||||
Inner UV intensity | ≥13800 μW/cm3 | ||||||
Ozone concentration | ≤0 mg/m3 | ||||||
Lamp life | ≥5000 hours | ||||||
Negative oxygen ion emission | ≤6×106 ions/m3 | ||||||
Power supply | 220V/50Hz | ||||||
Noise level | ≤50 dB(A) |