Home SBH Refrigerated Air Dryer

SBH Refrigerated Air Dryer

Introduction of the Refrigerated Air Dryer
The SBH refrigerated air dryer is a great compressed air treatment solution, and is widely used in various fields with attractive price.
On the basis of up-to-date technologies, the refrigerated dryer is composed of advanced parts. It can be used in conjunction with a LG series screw compressor, so as to remove moisture from the compressed air, and ensure the pressure dew point of 3-10℃.


Working Conditions of the Refrigerated Air Dryer
Air inlet temperature: ≤45℃
Working pressure: 7bar (application range:6~10bar)
Environment temperature: Air cooling (A):≥2℃, ≤38℃
Pressure dew point: 3-10℃(7bar)
Cooling water temperature: t≤32℃
Cooling water pressure:2~4bar
Installation of refrigerated air dryer: This range of compressed air dryer can be installed on the indoor concrete floor without foundation, and the space left around the product should be equal or greater than 1 meter.

SBH Refrigerated Air Dryer

Technical Parameters of Air-cooled Refrigerated Air Dryer
Model Handling capacity Power supply Power consumption Size of joint Weight Dimension
m3/min (V/ph/Hz) (kW) (Kg) (L×W×H)
SBH-10NF 1.25 220/1/50 0.83 ZG1" 50 640×435×580
SBH-20NF 2.6 0.86 ZG1" 57 600×495×670
SBH-30NF 3.8 1.00 ZG1" 59 600×495×670
SBH-50NF 5.6 1.63 ZG1" 78 760×515×750
SBH-60NF 6.9 1.75 ZG1½" 120 820×600×880
SBH-75NF 8.5 1.95 ZG1½" 122 820×600×880
SBH-100NF 10.7 2.59 ZG2" 155 1150×590×1000
SBH-120NF 14 380/3/50 2.99 ZG2" 175 1190×650×1030
SBH-150NF 18 3.39 DN50 220 1400×800×1030
SBH-200NF 23 4.18 DN50 350 1560×800×1270
SBH-250NF 28.5 5.28 DN80 400 1740×800×1270
SBH-300NF 32 6.78 DN80 500 1760×950×1488
SBH-350NF 36 7.58 DN80 520 1760×950×1488
SBH-400NF 46 7.82 DN80 650 2140×950×1488
SBH-500NF 56 9.62 DN100 680 2140×950×1488
SBH-600NF 65 11.84 DN125 800 2090×1110×1520
SBH-800NF 85 15.36 DN125 950 2140×1110×1616

Technical Parameters of Water-cooled Refrigerated Air Dryer
Model Handling capacity Power supply Power consumption Water consumption Cooling water joint Weight Dimension
m3/min (V/ph/Hz) (kW) (T/H) (Kg) (L×W×H mm)
SBH-100NW 10.7 220/1/50 2.2 1.8 ZG1" 145 1150×540×1000
SBH-120NW 14 380/3/50 2.6 2.4 ZG1" 165 1190×600×1030
SBH-150NW 18 3 3 ZG1" 210 1400×800×1030
SBH-200NW 23 3.7 3.7 ZG1" 330 1420×800×1270
SBH-250NW 28.5 4.8 4.4 ZG1½" 380 1740×800×1270
SBH-300NW 32 6.3 5.9 ZG1½" 480 1660×950×1488
SBH-350NW 36 7.1 5.9 ZG1½" 500 1660×950×1488
SBH-400NW 46 7.1 7.4 ZG1½" 640 1940×950×1488
SBH-500NW 56 8.9 8.9 ZG1½" 660 1940×950×1488
SBH-600NW 65 10.8 11.1 ZG1½" 760 2090×1000×1383
SBH-800NW 85 13.8 12.4 ZG2" 930 2100×1012×1615
SBH-100NW 110 18.6 14.6 ZG2" 1350 2068×1055×1688

Flow Chart of the Refrigerated Air Dryer
1. Heat exchanger2. Evaporator3. Gas/Liquid separator4. Anti-clogging drain filter5. Manual draining valve6. Refrigerated compressor7. Aspirating filter8. Vaporization9. Separator10. Gas/Liquid mixer11. Thermal expansion valve12. View monitor13. Dry filter14. Tank15. Hot gas by-pass valve16. Water adjustable valve17. Water filter18. Condenser (Air-cooling)19. Condenser (Water-cooling)20. Pre-cooler (Water-cooling)21. Pre-cooler (Air-cooling)22. Auto-drainer

Recommended Products
Hot Products