Introduction of the Refrigerated Air Dryer
The SBH refrigerated air dryer is a great compressed air treatment solution, and is widely used in various fields with attractive price.
On the basis of up-to-date technologies, the refrigerated dryer is composed of advanced parts. It can be used in conjunction with a LG series screw compressor, so as to remove moisture from the compressed air, and ensure the pressure dew point of 3-10℃.
Working Conditions of the Refrigerated Air Dryer
Air inlet temperature: ≤45℃
Working pressure: 7bar (application range:6~10bar)
Environment temperature: Air cooling (A):≥2℃, ≤38℃
Pressure dew point: 3-10℃(7bar)
Cooling water temperature: t≤32℃
Cooling water pressure:2~4bar
Installation of refrigerated air dryer: This range of compressed air dryer can be installed on the indoor concrete floor without foundation, and the space left around the product should be equal or greater than 1 meter.
Technical Parameters of Air-cooled Refrigerated Air Dryer Model | Handling capacity | Power supply | Power consumption | Size of joint | Weight | Dimension |
m3/min | (V/ph/Hz) | (kW) | (Kg) | (L×W×H) |
SBH-10NF | 1.25 | 220/1/50 | 0.83 | ZG1" | 50 | 640×435×580 |
SBH-20NF | 2.6 | 0.86 | ZG1" | 57 | 600×495×670 |
SBH-30NF | 3.8 | 1.00 | ZG1" | 59 | 600×495×670 |
SBH-50NF | 5.6 | 1.63 | ZG1" | 78 | 760×515×750 |
SBH-60NF | 6.9 | 1.75 | ZG1½" | 120 | 820×600×880 |
SBH-75NF | 8.5 | 1.95 | ZG1½" | 122 | 820×600×880 |
SBH-100NF | 10.7 | 2.59 | ZG2" | 155 | 1150×590×1000 |
SBH-120NF | 14 | 380/3/50 | 2.99 | ZG2" | 175 | 1190×650×1030 |
SBH-150NF | 18 | 3.39 | DN50 | 220 | 1400×800×1030 |
SBH-200NF | 23 | 4.18 | DN50 | 350 | 1560×800×1270 |
SBH-250NF | 28.5 | 5.28 | DN80 | 400 | 1740×800×1270 |
SBH-300NF | 32 | 6.78 | DN80 | 500 | 1760×950×1488 |
SBH-350NF | 36 | 7.58 | DN80 | 520 | 1760×950×1488 |
SBH-400NF | 46 | 7.82 | DN80 | 650 | 2140×950×1488 |
SBH-500NF | 56 | 9.62 | DN100 | 680 | 2140×950×1488 |
SBH-600NF | 65 | 11.84 | DN125 | 800 | 2090×1110×1520 |
SBH-800NF | 85 | 15.36 | DN125 | 950 | 2140×1110×1616 |
Technical Parameters of Water-cooled Refrigerated Air Dryer Model | Handling capacity | Power supply | Power consumption | Water consumption | Cooling water joint | Weight | Dimension |
m3/min | (V/ph/Hz) | (kW) | (T/H) | (Kg) | (L×W×H mm) |
SBH-100NW | 10.7 | 220/1/50 | 2.2 | 1.8 | ZG1" | 145 | 1150×540×1000 |
SBH-120NW | 14 | 380/3/50 | 2.6 | 2.4 | ZG1" | 165 | 1190×600×1030 |
SBH-150NW | 18 | 3 | 3 | ZG1" | 210 | 1400×800×1030 |
SBH-200NW | 23 | 3.7 | 3.7 | ZG1" | 330 | 1420×800×1270 |
SBH-250NW | 28.5 | 4.8 | 4.4 | ZG1½" | 380 | 1740×800×1270 |
SBH-300NW | 32 | 6.3 | 5.9 | ZG1½" | 480 | 1660×950×1488 |
SBH-350NW | 36 | 7.1 | 5.9 | ZG1½" | 500 | 1660×950×1488 |
SBH-400NW | 46 | 7.1 | 7.4 | ZG1½" | 640 | 1940×950×1488 |
SBH-500NW | 56 | 8.9 | 8.9 | ZG1½" | 660 | 1940×950×1488 |
SBH-600NW | 65 | 10.8 | 11.1 | ZG1½" | 760 | 2090×1000×1383 |
SBH-800NW | 85 | 13.8 | 12.4 | ZG2" | 930 | 2100×1012×1615 |
SBH-100NW | 110 | 18.6 | 14.6 | ZG2" | 1350 | 2068×1055×1688 |
Flow Chart of the Refrigerated Air Dryer | 1. Heat exchanger2. Evaporator3. Gas/Liquid separator4. Anti-clogging drain filter5. Manual draining valve6. Refrigerated compressor7. Aspirating filter8. Vaporization9. Separator10. Gas/Liquid mixer11. Thermal expansion valve12. View monitor13. Dry filter14. Tank15. Hot gas by-pass valve16. Water adjustable valve17. Water filter18. Condenser (Air-cooling)19. Condenser (Water-cooling)20. Pre-cooler (Water-cooling)21. Pre-cooler (Air-cooling)22. Auto-drainer |