Timing Control Electronic Ignitor
The timing control electronic ignitor can achieve 10-minute timing. Apart from the function of standard product, the timing control product can also ensure the trigger pulse to be generated in the specified period of time. Thus, the phenomena of incomplete trigger, flickering of lamp or continuous trigger when the lamp fails to work can be avoided. Then, the ballast and lamp tube can be protected effectively.
The timing control electronic ignitor stops trigger automatically when the time comes to the preset working time. Meanwhile, after the supply voltage is switched off, the timing control function needs to be reset.
Technical Parameters
Model | Lamp Power | Supply Voltage | Frequency | Response/Cut-off Voltage | Impulse Height | Impulse Width | Max. Lamp Current | Max. Temperature of Enclosure | Dimension (mm) | ||
L | L1 | H | |||||||||
CD0005E-D10 | 70-400W | 220-240V | 50-60 Hz | ≤198V/ ≥ 170V | 3.5-5kV | ≥1uS | 5A | 85°C | 92 | 80 | 36 |
Related Names
Ignitor with Timer | Timing Trigger