Functions Supply voltage: 200V—240VAC; Frequency range: 50HZ—60HZ Control mode: manual or automatic mode (selectable) Time control stage: T1 (needle valve gate opening), T2 (needle valve gate delayed opening). Time setting range: 0-999.9S Input signal: 220VAC, 110VAC, 24VDC (the output voltage of the injection molding machine) or digital signal. Output control voltage: 220VAC, 110VAC or 24VDC (selectable) Output control valve: pneumatic or hydraulic valve Technical specifications
Item | |
Supply voltage | 185V-250VAC |
Frequency range | 50HZ-60HZ |
Operating temperature | -20 ℃ -60 ℃ |
Storage temperature | -30 ℃ -70 ℃ |
Fuse | 3A, 6mm × 30mm, 1 ‰ sec |
Input signal | 24VDC or digital signal |
Output voltage | 12VDC, 24VDC, 110VAC, 220VAC |
Output control valve | Pneumatic or hydraulic valve |
Time control stage | T1: needle valve gate opening; T2: needle valve gate delayed opening. |
Time control accuracy | 0.1s |
Product gallery TMS-001-2 L245*305*H240mm
TMS-001-4 L295*W305*H240mm
TMS-001-(5-6) L400*W305*H240 mm
TMS-001-12 L400*W305*H445mm
TMS-001-4 (with four pneumatic valves) L295*W305*H240mm
All models shown here are standard hot runner sequential controller models. Customized options are available to meet unique customer requirements.