Atlas Copco Booster AirCompressor
Atlas Cocpo oil free booster
ZD 1200-4000 & VSD
ZDT 800-1200 (air cooling)
40bar/50-60Hz
AtlasCopco ZD booster air compressor offers entrancingdesign
Despite the long compressor compressors are placed ina separate room, but the situations in the application of high pressure gas(such as PET blow molding or aerospace applications), the air is still a keysupply source. Poor performance or poor quality of the air compressor woulddamage the continuity of your work, profitability, and even the reputation ofyour product and business.
In addition, the generation of compressed airconsumes a lot of energy, therefore, a wise choicewill bring you the real energy savings. So, it is important that you simplywant to see things other than purchase price, considering the equipment and itscomponents to the quality and service life, operating costs, installation andset up a possible shift the costs incurred, the direct costs of energyconsumption and maintenance and accidents caused by the indirect costs ofdowntime and production losses.
ZD Atlas Copcobooster air compressor opens a new era!
Not being “hidden” inthe compressor roombut installed in youroperating room, ZD series Atlas Copco booster air compressor is committed toimproving the overall quality of the process, and saving cost at all levels. Unique combination of oil-freescrew and piston technologymakes ZD booster air compressor become the most advanced aircompressor in the field.
Always ensure real innovation
Atlas Copco ZD booster air compressor features
ZD series Atlas Copcobooster air compressor design standards is based on asurvey conducted by Atlas Copco, the survey collected10 customer needs. In fact, these requirements are neither innovative nor demanding,but over the years for improving the performance of reciprocating aircompressor 40bar more concentrated in some subtle, but no attempt to rethinkthe basis for process improvement.
Now, Atlas Copco designedone new system to meet those requirements that other similar equipment can not.This is not limited to improving details, but is achieved through thoroughinnovation.
ZD and ZD VSD
40bar oil free
Used
CE400V-50Hz IEC
ASME440V-60Hz IEC
ASME460V-60Hz UL/CSA
U&I
Optional
Dew point meter, 40bar;
HAT(40<T°C<50);
ZR HAT D, silenced enclosure
Air Cooling ZD
ZD Air-cooled 50Hz Model |
| ||||
bar(e) | psig | l/s | m³/h | cfm | |
ZD 800-50 air-cooled | 40 | 580 | 220 | 792 | 466 |
ZD 1000-50 air-cooled | 40 | 580 | 260 | 936 | 551 |
ZD 1200-60 air-cooled | 40 | 580 | 334 | 1202 | 708 |
ZD Air-cooled 60Hz Model |
| ||||
bar(e) | psig | l/s | m³/h | cfm | |
ZD 800-60 air-cooled | 40 | 580 | 236 | 850 | 500 |
ZD 1000-60 air-cooled | 40 | 580 | 282 | 1015 | 598 |
ZD 1200-60 air-cooled | 40 | 580 | 316 | 1138 | 670 |
ZD 50Hz | ZD air flow | ||
Nm³/h | m³/h FAD | cfm FAD | |
ZD 1200 | 1067 | 1160 | 683 |
ZD 1400 | 1275 | 1386 | 816 |
ZD 1600 | 1443 | 1570 | 924 |
ZD 2100 | 1967 | 2139 | 1259 |
ZD 2500 | 2271 | 2470 | 1454 |
ZD 2750 | 2576 | 2801 | 1649 |
ZD 3050* | 2769 | 3010 | 1772 |
ZD 3350* | 3076 | 3345 | 1969 |
ZD 3750* | 3456 | 3759 | 2213 |
ZD 4000* | 3696 | 4018 | 2365 |
ZD 60Hz | ZDair flow | ||
Nm³/h | m³/h FAD | cfm FAD | |
ZD 1200 | 1022 | 1113 | 655 |
ZD 1400 | 1252 | 1361 | 801 |
ZD 1600 | 1469 | 1599 | 941 |
ZD 1900 | 1752 | 1905 | 1121 |
ZD 2300 | 2110 | 2294 | 1350 |
ZD 2550 | 2387 | 2596 | 1528 |
ZD 3100 | 2831 | 3078 | 1812 |
ZD 3500 | 3155 | 3431 | 2020 |
ZD 4000 | 3715 | 4040 | 2378 |
ZD VSD | Air flow | ||
Nm³/h | m³/h FAD | cfm FAD | |
ZD 1200 VSD | 444/1059 | 483/1152 | 284/678 |
ZD 1400 VSD | 444/1266 | 483/1376 | 284/810 |
ZD 2300 VSD | 1020/2071 | 1109/2252 | 653/1326 |
ZD 2800 VSD | 1020/2444 | 1109/2658 | 653/1565 |
ZD 3500 VSD(1) | 1455/3238 | 1583/3522 | 932/2073 |
ZD 4100 VSD(1) | 1455/3637 | 1583/3956 | 932/2328 |
Condition (FAD):
Temperature: 20℃; RH: 0%; Inlet pressure: 1bar abs
Condition (Nm³/h):
Temperature: 0℃; RH: 0%; Inlet pressure: 1.013 bar abs