Description
Model | Dimension (mm) L×B×H | Net Weight (kg) | Instruction |
120GF153-6T | 4045×1600×1980 | 5500 | Closed cooling method for vertical water box with fan |
120GF153-PwT | 3505×1600×1985 | 5200 | Closed cooling method for horizontal water box with more than one fan |
200GF-PT | 4045×1600×1980 | 5500 | Closed cooling method for vertical water box with fan |
200GF-PwT | 3505×1600×1985 | 5200 | Closed cooling method for horizontal water box with more than one fan |
Conditions for Using
1. For pressurized natural gas generator in this natural gas generator set, the pressure for air inflow is 100kPa~300kPa; for unpressurized natural gas generator, the pressure for air inflow is 30kPa~300kPa.
2. If the distance between the natural gas and the pressure regulating valve for air inflow is 1m or nearer, the temperature of the natural gas should not surpass 40℃.
3. The content of the methane in natural gas for this natural gas generator set should not be lower than 70% and the low heating value is 32MJ/Nm3~45MJ/Nm3.
4. The content of H2S should not surpass 20mg/Nm3 and the total content of sulfur should not surpass 480mg/Nm3.
5. The granularity of the impurity should not surpass 5μm and the content of the impurity should not surpass 30mg/Nm3. There should not be any free water, clean oil, etc.
Technologies Used
1. Electrical fuel gas mixing technology is used.
2. The natural gas generator set is designed with low-pressure air inflow technology.
3. Automatic control technology for burning.
4. A safe conveying system is used in this natural gas generator set.
Technical Parameters
Name of Parameter | Value of Parameter | |||
Model of the set | 120GF153-6T | 120GF153-PwT | 200GF-PT | 200GF-PwT |
Model of gas engine | T4190-2B | T4190ZL-2 | ||
Model of generator | 1FC6 352-6LA42 | 1FC6 354-6LA42 | ||
Rated power(kW) | 120 | 200 | ||
Rated current(A) | 217 | 288 | ||
Rated voltage(V) | 400 | |||
Rated frequency(Hz) | 50 | |||
Rated rotated speed(r/min) | 1000 | |||
Rated power factor(cosφ) | 0.8(lag) | |||
The number of phase and the wiring method | Three coils wired by three phase lines or three coils wired by three phase lines and one zero line. | |||
Way for adjusting pressure | Automatic adjusting pressure | |||
Excitation method | Brushless excitation | |||
Starting up method | 24VDC Electric starting system |
Technical Parameters
Name of Parameter | Value of Parameter | ||
Model | T4190-2B | T4190ZL-2 | |
Number of cylinder | 4 | ||
Arranging way of cylinders | Straightly arranged | ||
Diameter of cylinder(mm) | 190 | ||
Route(mm) | 210 | ||
Total displacement(L) | 23.82 | ||
Air inflow way | Naturally aspirated | Increasing the pressure by using the exhaust produced by the generator to promote the operation of the turbine, thus improve the inlet pressure. The intercooler for air inflow is also used. | |
Rated power(kW) | 140 | 200 | |
Rated rotate speed(r/min) | 1000 | ||
Min. stable rotate speed with empty load(r/min) | 600 | ||
Dimension(L×B×H) (mm) | 1175×1121×1630 | 1175×1120×1630 | |
Net weight(kg) | 2900 | 3000 |