1. For pressurized natural gas generator, the pressure for air inflow is 100kPa~300kPa; for unpressurized natural gas generator, the pressure for air inflow is 30kPa~300kPa.
2. If the distance between the natural gas and the pressure regulating valve for air inflow in this natural gas generator set is 1m or nearer, the temperature of the natural gas should not surpass 40℃.
3. The content of the methane in natural gas should not be lower than 70% and the low heating value is 32MJ/Nm3~45MJ/Nm3.
4. For the natural gas used in this natural gas generator set, the content of H2S should not surpass 20mg/Nm3 and the total content of sulfur should not surpass 480mg/Nm3.
5. The granularity of the impurity should not surpass 5μm and the content of the impurity should not surpass 30mg/Nm3.
6. There is no free water, clean oil, etc.
Technical Parameters
Name of Parameter | Value of Parameter |
Model of the set | 24GF47-T |
Model of gas engine | T1190ND |
Model of generator | TFW-24IV |
Rated power(kW) | 24 |
Rated current(A) | 43.3 |
Rated voltage(V) | 400 |
Rated frequency(Hz) | 50 |
Rated rotated speed(r/min) | 850 |
Rated power factor(cosφ) | 0.8(lag) |
The number of phase and the wiring method | Three coils wired by three phase lines or three coils wired by three phase lines and one zero line. |
Way for adjusting pressure | Automatic adjusting pressure |
Excitation method | Brushless excitation |
Starting up method | 24VDC Electric starting system |
Technical Parameters
Name of Parameter | Value of Parameter |
Model | T1190ND |
Number of cylinder | 1 |
Arranging way of cylinders | Straightly arranged |
Diameter of cylinder(mm) | 190 |
Route(mm) | 210 |
Total displacement(L) | 5.954 |
Air inflow way | Naturally aspirated |
Rated power(kW) | 30 |
Rated rotate speed(r/min) | 850 |
Min. stable rotate speed with empty load(r/min) | 450 |
Dimension(L×B×H) (mm) | 1490×900×1225 |
Net weight(kg) | 1250 |