Home Boiler Centrifugal Induced Draft Fan, G/Y6-41 Series

Boiler Centrifugal Induced Draft Fan, G/Y6-41 Series

G/Y6-41 series boiler induced draft fan (ID fan) is designed with low noise, stable running, high reliability, and long service life. It is primarily applied in industrial boilers powered by coals of diverse quality and equipped with dust removal device. In an industrial ventilation system, blower is set to introduce air whose temperature is within 80℃ into the room, and induced draft fan is used for exhausting dust out of the inner space, with the temperature of dust and gas to be no more than 250℃. A dust removal device is indispensable in front of a ventilation fan to protect it from the solid particle in the gas.

Boiler Centrifugal Induced Draft Fan, G/Y6-41 Series

G6-41 Boiler Blower
NO. Rotating speed (r/min) Flow (m3/h) Total pressure (Pa) Motor power (kW)
3.3A 2825 1090-2301 954-1936 1.1
5.4A 1420 2357-5514 833-1264 3
6.4A 1440 4210-10348 1029-1852 5.5
7.1A 1440 4418-11350 1234-2244 7.5
8.5A 1470 6482-17330 2518-3253 18.5

Y6-41 Boil Blower
NO. Rotating speed (r/min) Flow (m3/h) Total pressure (Pa) Motor power (kW)
4.5C 2025 2317-4970 1667-2327 4
3250 2574-5522 2058-2873 5.5
5.4C 2600 4234-10002 1440-2528 7.5
2900 4350-8901 2568-3240 11
7.1C 2100 11408-16300 1975-2794 15
2200 9607-17970 1790-3369 18.5
2350 8728-16898 2800-3746 22
9C 1640 13964-28130 1662-2955 22
1750 11159-29734 1587-3106 30
1960 12498-25662 3109-3892 37
10C 1600 16620-35157 2710-3611 37
11.2C 1480 24961-47591 2043-3618 45