About UL1028
Manufacture standard: UL758
Rated voltage: 600Vac
Temperature range: -40-105℃
Voltage of spark testing: 6kV/AC
Conductor: Bare copper or tinned copper
Insulator: PVC
Flame retardant performance: Passing UL VW-1 and CSA FT1 vertical flame tests
Environmental protection: ROHS standard
Color: Black, brown, red, orange, yellow, green, blue, purple, gray and white.
Application: Internal wiring and electronic equipment
Conductor | Insulator | Conductor resistance (Tinned copper) | Standard length | |||||
Wire gauge | Structure | Diameter | Nominal thickness | Min. thickness | Nominal external diameter | Max. value (20℃) | English unit | Metric unit |
AWG | Number of wires/Wire diameter (mm) | mm | mm | mm | mm | Ω /km | FT | m |
22 | 17/0.16 | 0.76 | 1.14 | 1.02 | 3.1±0.15 | 59.4 | 2000 | 610 |
20 | 26/0.16 | 0.94 | 1.14 | 1.02 | 3.3±0.15 | 37.4 | ||
18 | 41/0.16 | 1.18 | 1.14 | 1.02 | 3.5±0.15 | 23.5 | ||
16 | 26/0.254 | 1.50 | 1.14 | 1.02 | 3.8 ± 0.15 | 14.6 | 1000 | 305 |
14 | 41/0.254 | 1.18 | 1.14 | 1.02 | 4.2 ± 0.15 | 9.15 | ||
12 | 65/0.254 | 2.36 | 1.14 | 1.02 | 4.7 ± 0.15 | 5.75 | ||
10 | 105/0.254 | 3.40 | 1.14 | 1.02 | 5.8 ± 0.15 | 3.55 | ||
8 | 119/0.30 | 4.30 | 1.14 | 1.02 | 6.7 ± 0.15 | 2.27 | ||
6 | 189/0.30 | 5.40 | 1.52 | 1.37 | 8.6 ± 0.20 | 1.41 | 500 | 152.5 |
Notes: 1. We can manufacture the hook-up wire according to client's drawing or sample. 2. The structure of conductor is either solid or stranded. For example, "17/0.16" means the conductor is stranded by 17 wires and the wire has a diameter of 0.16 mm. |