About UL2464
Manufacture standard: UL758
Rated voltage: 300 Vac
Temperature range: -40 to 80℃
Conductor: Bare copper
Insulator: PVC
Flame retardant performance: Passing UL VW-1 and CSA FT1 vertical flame tests
Environmental protection: ROHS standard
Color: Black, brown, red, orange, yellow, green, blue, purple, gray and white.
Application: Internal wiring and electronic equipment
Conductor | Core number | Insulator | Shielding material | Weaving structure | Protective cover | Conductor resistance (Bare copper) | Standard length | |||||
Wire gauge | Structure | Diameter | Nominal thickness | Nominal external diameter | Nominal thickness | Nominal external diameter | Max. value (20℃) | English unit | Metric unit | |||
AWG | Number of wires/Wire diameter (mm) | mm | mm | mm | mm | mm | Ω /km | FT | m | |||
28 | 7/0.127 | 0.38 | 2 | 0.23 | 0.9±0.1 | AL-mylar | 0.12 | 0.76 | 4.0 | 223 | 2000 | 610 |
3 | 0.9±0.1 | AL-mylar | 0.76 | 4.0 | ||||||||
4 | 0.9±0.1 | AL-mylar | 0.76 | 4.5 | ||||||||
5 | 0.9±0.1 | AL-mylar | 0.76 | 4.5 | ||||||||
6 | 0.9±0.1 | AL-mylar | 0.76 | 5.0 | 1000 | 305 | ||||||
7 | 0.9±0.1 | AL-mylar | 0.76 | 5.0 | ||||||||
8 | 0.9±0.1 | AL-mylar | 0.76 | 5.0 | ||||||||
9 | 0.9±0.1 | AL-mylar | 0.76 | 5.5 | ||||||||
10 | 0.9±0.1 | AL-mylar | 0.76 | 5.8 | ||||||||
26 | 7/0.16 | 0.48 | 2 | 0.23 | 1.0±0.1 | AL-mylar | 0.12 | 0.76 | 4.0 | 140 | 2000 | 610 |
3 | 1.0±0.1 | AL-mylar | 0.76 | 4.5 | ||||||||
4 | 1.0±0.1 | AL-mylar | 0.76 | 4.5 | ||||||||
5 | 1.0±0.1 | AL-mylar | 0.76 | 5.0 | 1000 | 305 | ||||||
6 | 1.0±0.1 | AL-mylar | 0.76 | 5.0 | ||||||||
7 | 1.0±0.1 | AL-mylar | 0.76 | 5.0 | ||||||||
8 | 1.0±0.1 | AL-mylar | 0.76 | 5.5 | ||||||||
9 | 1.0±0.1 | AL-mylar | 0.76 | 5.8 | ||||||||
10 | 1.0±0.1 | AL-mylar | 0.76 | 6.1 | ||||||||
24 | 11/0.16 | 0.61 | 2 | 0.23 | 1.1±0.1 | AL-mylar | 0.12 | 0.76 | 4.5 | 87.6 | 2000 | 610 |
3 | 1.1±0.1 | AL-mylar | 0.76 | 4.5 | ||||||||
4 | 1.1±0.1 | AL-mylar | 0.76 | 4.8 | ||||||||
5 | 1.1±0.1 | AL-mylar | 0.76 | 5.1 | 1000 | 305 | ||||||
6 | 1.1±0.1 | AL-mylar | 0.76 | 5.5 | ||||||||
7 | 1.1±0.1 | AL-mylar | 0.76 | 5.5 | ||||||||
8 | 1.1±0.1 | AL-mylar | 0.76 | 5.8 | ||||||||
9 | 1.1±0.1 | AL-mylar | 0.76 | 6.2 | ||||||||
10 | 1.1±0.1 | AL-mylar | 0.76 | 6.5 | ||||||||
22 | 17/0.16 | 0.76 | 2 | 0.23 | 1.3±0.1 | AL-mylar | 0.12 | 0.76 | 4.8 | 55.4 | 1000 | 305 |
3 | 1.3±0.1 | AL-mylar | 0.76 | 5.0 | ||||||||
4 | 1.3±0.1 | AL-mylar | 0.76 | 5.2 | ||||||||
5 | 1.3±0.1 | AL-mylar | 0.76 | 5.8 | ||||||||
6 | 1.3±0.1 | AL-mylar | 0.76 | 6.0 | ||||||||
7 | 1.3±0.1 | AL-mylar | 0.76 | 6.0 | ||||||||
8 | 1.3±0.1 | AL-mylar | 0.76 | 6.5 | ||||||||
9 | 1.3±0.1 | AL-mylar | 0.76 | 7.0 | ||||||||
10 | 1.3±0.1 | AL-mylar | 0.76 | 7.3 | ||||||||
20 | 26/0.16 | 0.94 | 2 | 0.23 | 1.5±0.1 | AL-mylar | 0.12 | 0.76 | 5.1 | 34.6 | 1000 | 305 |
3 | 1.5±0.1 | AL-mylar | 0.76 | 5.5 | ||||||||
4 | 1.5±0.1 | AL-mylar | 0.76 | 5.8 | ||||||||
5 | 1.5±0.1 | AL-mylar | 0.76 | 6.2 | ||||||||
6 | 1.5±0.1 | AL-mylar | 0.76 | 6.7 | ||||||||
7 | 1.5±0.1 | AL-mylar | 0.76 | 6.7 | ||||||||
8 | 1.5±0.1 | AL-mylar | 0.76 | 7.0 | 500 | 152.5 | ||||||
9 | 1.5±0.1 | AL-mylar | 0.76 | 7.7 | ||||||||
10 | 1.5±0.1 | AL-mylar | 0.76 | 8.1 | ||||||||
18 | 41/0.16 | 1.18 | 2 | 0.23 | 1.8±0.1 | AL-mylar | 0.12 | 0.76 | 5.7 | 21.8 | 1000 | 305 |
3 | 1.8±0.1 | AL-mylar | 0.76 | 6.0 | ||||||||
4 | 1.8±0.1 | AL-mylar | 0.76 | 6.5 | ||||||||
5 | 1.8±0.1 | AL-mylar | 0.76 | 7.0 | 500 | 152.5 | ||||||
6 | 1.8±0.1 | AL-mylar | 0.76 | 7.5 | ||||||||
7 | 1.8±0.1 | AL-mylar | 0.76 | 7.5 | ||||||||
8 | 1.8±0.1 | AL-mylar | 0.76 | 8.0 | ||||||||
9 | 1.8±0.1 | AL-mylar | 0.76 | 8.8 | ||||||||
10 | 1.8±0.1 | AL-mylar | 0.76 | 9.4 | ||||||||
Notes: 1. We can manufacture the hook-up wire according to client's drawing or sample. 2. The structure of conductor is either solid or stranded. For example, "7/0.127" means the conductor is stranded by 7 wires and the wire has a diameter of 0.127 mm. |