Y5-47II series centrifugal fan has seen some modification in performance comparing with its original model, Y5-47. To better meet the diverse application requirements of industrial boilers with dust removal devices, we have additionally developed 8 different models: 4D, 5D, 6D, 7D, 10D, 11D, 12D, and 12.4D. That said, we have induced draft fans provided for any industrial boilers ventilation systems that meet the required conditions. The max temperature is allowed to be 200℃.
NO. | Rotating speed (r/min) | Flow (m3/h) | Total pressure (Pa) | Motor power (kW) |
4C | 3300 | 2751-5190 | 1393-1922 | 4 |
2900 | 2417-4561 | 1079-1481 | 3 | |
5C | 2900 | 4723-8909 | 1687-2324 | 7.5 |
2620 | 4267-8048 | 1373-1893 | 5.5 | |
6C | 2850 | 8020-15129 | 2452-3364 | 18.5 |
2620 | 7372-13908 | 2069-2844 | 15 | |
4D | 2870 | 2393-4514 | 1059-1451 | 3 |
5D | 2900 | 4723-8909 | 1687-2324 | 7.5 |
6D | 2930 | 8245-15553 | 2589-3550 | 18.5-22 |
7C | 2580 | 11529-21747 | 2746-3756 | 30 |
2320 | 10367-19556 | 2206-3040 | 22 | |
2200 | 9830-18545 | 1991-2736 | 18.5 | |
2050 | 9159-17280 | 1716-2373 | 15 | |
8C | 2020 | 13474-25417 | 2187-3001 | 30 |
1860 | 12407-23404 | 1853-2550 | 22 | |
1900 | 18045-34039 | 2452-3364 | 45 | |
1800 | 17095-32247 | 2197-3020 | 37 | |
10D | 1480 | 19281-36371 | 1834-2697 | 37 |
11D | 1480 | 25663-48410 | 2216-3050 | 35 |
12D | 1480 | 33318-62850 | 2638-3628 | 75-90 |
12.4D | 1480 | 36762-69347 | 2824-3874 | 110 |