Product Name: High Frequency Monopolar Electrosurgical Unit (ESU)
Product Model: DD-2J
Product Features
Various functions with compact and light design
Monopolar cut (pure cut, blend 1, and blend 2)
Monopolar coag (standard coag)
Bipolar coag, fully meet different surgery requirement.
Tissue Monitoring Technology
The tissue monitoring technology monitors the tissue density, especially in polypectomies and papillotomies. Cutting is divided into cut and pause processes, so that coagulation occurs during each pause. The system is smart enough to change the pause interval as tissue density changes, thus producing a fine cutting and coagulation effect.
Patient Return Electrode Monitoring (PREM)
REM (Return Electrode Monitoring) monitors the range of the contact area between the patient and the neutral plate. If the size is not appropriate, the monitor will automatically stop the high frequency current with an audible alarm to minimize the danger of burns. It is compatible with other surgical equipment, and is useful in endoscopy and optimum smoke evacuation systems. The patient monitor has a waterproof panel operation and microcomputer control in a two zone LED digital display.
Application
General surgery, gastroenterology, dermatology, vascular surgery, obstetrics and gynecology.
ORL/ ENT surgery, neurosurgery, orthopedics & plastic surgery, and other open surgery.
Working Mode | Max Power | Peak Voltage | |||
Monopolar Cut | Pure Cut | 350W | 1500V | ||
Blend 1 | 250W | 2000V | |||
Blend 2 | 150W | 2500V | |||
Monopolar Coag | Standard Coag | 120W | 3500V | ||
Bipolar Coag | Bipolar Coag | 50W | 620V | ||
Electrical Requirement | |||||
Operating Voltage | 220V ± 22V | Measuring Frequency | 530KHz ± 2 | ||
Monopolar Rate Load | 500Ω | Bipolar Rate Load | 100Ω | ||
Max Input Currency | 1400VA | ||||
Environmental Conditions for Use | |||||
Condition | Range | ||||
Temperature | 5 0°C to 40 °C | ||||
Relative humidity | ≤ 95% non-condensing | ||||
Pressure | 7 00 hPa to 1060 hPa | ||||
Environmental Conditions for Transport and Storage | |||||
Condition | Range | ||||
Temperature | -4 0°C to 55 °C | ||||
Relative humidity | ≤ 9 3 % non-condensing | ||||
Pressure | 5 00 hPa to 1060 hPa | ||||
Dimension (L×W×H) | 350mm × 320 mm × 100mm | ||||
Weight | 18kg |
Code | Accessories Name | Quantity |
1 | Electrosurgical Unit | 1 |
2 | Reusable ESU Pencil | 2 |
3 | Disposable Reusable patient plate | 5 |
4 | Reusable patient plate cable | 1 |
5 | Reusable Bipolar forceps | 1 |
6 | Reusable Bipolar cable | 1 |
7 | Double Footswitch | 1 |
8 | Power cable | 1 |
8 | Service Manual | 1 |