The HM-713 series low power consumption combustible gas detector takes advantage of high-sensitivity semiconductor sensor and microprocessor controller. It shows strong alarm sensitivity and conformability. The product is designed with ceiling installation mode. Its base can connect with the 86×86mm junction box. Meanwhile, the product can provide the manual testing and automatic reset functions.
The low power consumption combustible gas detector can detect the natural gas and liquefied petroleum gas. With the fault automatic diagnosis indication available, if the product has the problem, the yellow LED indicator would give the indication to notify the user of the situation. Additionally, the product is up to the standard of GB15322.2-2003.
Model | Operating Voltage | Description |
HM-713LS-AC | AC110V or AC200-240V | Alarm Indication: 75dB/m Alarm Sound and Red LED Indication |
HM-713LVS-AC | AC110V or AC200-240V | Alarm Indication: Sound and Flash AlarmBasic Function: Outputting the DC12V Pulse Voltage to Drive Electromagnetic Valve to Close the Gas Source |
HM-713LC-AC | AC110V or AC200-240V | Alarm Indication: Sound and Flash AlarmBasic Function: Outputting a N.C./N.O. Signal to Connect with Alarm Controller |
HM-713LC-DC | DC9-24V | Basic Function: Utilizing Low Power Consumption Sensor, Outputting A Relay Signal to the Alarm Controller |
HM-713NC-DC | DC9-24V | Basic Function: Adopting High Power Consumption Sensor, Outputting A Relay Signal to the Alarm Controller |
Model | HM-713LS-AC | HM-713LVS-AC | HM-713LC-AC | HM-713LC-DC | HM-713NC-DC |
Type | Independent Type | Independent Type with 12V Pulse Output to Drive Electromagnetic Valve | Network Type | Network Type | Network Type |
Operating Voltage | AC110V or 220V | AC110V or 220V | AC110V or 220V | DC9-24V | DC9-24V |
Sensor | Semiconductor Sensor | ||||
Alarm Concentration | 6% Lower Explosive Limit (± 3%) of Natural Gas | ||||
Alarm Sound Pressure | 75dB/m | ||||
Alarm Output | Not Available | 12V Pulse Output | Normally Closed or Normally Open Relay Output | Normally Closed or Normally Open Relay Output | Normally Closed or Normally Open Relay Output and 12V Pulse Output |
Alarm Resetting | Automatic resetting when the combustible gas concentration is below the alarm concentration | ||||
Relay Type | 1C (SPDT) Contact Load: 3A 250VAC/30VDC | ||||
Working Environment | Temperature Range: -10℃ ~ 55℃Humidity Range: 10%~95% RH (No Condensation Phenomenon) | ||||
Dimension | Ф122×40mm |
Related Names
Ceiling Mounted Detector | Natural Gas Sniffer | Explosive Gas Detector