Considering the power monitoring, electricity metering and power quality analyzing needs of electric systems, public facilities, intelligent buildings as well as industrial and mining enterprises, this PD19 series power quality monitor is specially designed.
Our product can precisely measure all the commonly-used electrical parameters of three-phase power grid, such as voltage, current, frequency, active power, reactive power, apparent power, power factor and others, and it also realizes 4-quadrant electricity measurement, U/I/P/Q demand detection, bi-directional electricity metering, multi-rate electricity calculation, automatic data recording, analog input monitoring, as well as digital input monitoring. Meanwhile, communication port, analog output, relay output, energy pulse output and other functions are also achieved.
Item | Data | ||
Accuracy | Electricity: Class 0.5Active energy: Class 0.5SReactive energy: Class 1Analog output: Class 0.5DC measurement: Class 0.5 | ||
Display | Dot-matrix LCD with Chinese/English menu or 12 digit LED | ||
Signal Input | Wiring Mode | 3P4W (Y34), 3P3W (V33) | |
Voltage | Rated Value | AC380V / AC100V | |
Overload | Continuous: 1.2 timesInstantaneous: 2 times/10 seconds | ||
Power Consumption | < 1VA for each phase | ||
Impedance | >300kΩ | ||
Current | Rated Value | AC5A /AC1A | |
Overload | Continuous: 1.2 timesInstantaneous: 10 times/5seconds | ||
Power Consumption | < 0.4VA for each phase | ||
Impedance | < 20mΩ | ||
Electricity Calculation | Two-way active and reactive electricity | ||
Power Supply | Working Range | AC/DC: 80~270V | |
Power | < 5VA | ||
Function Module | Electricity Pulse | Passive optical coupler isolated output, and the pulse width is fixed at 80ms±20% | |
Communication | Port: 2 RS-485 portsProtocol: Modbus-RTU | ||
Baud rate: 1200~19200bpsError correction: N81, E81, O81 | |||
The second RS485 port can be changed to follow the protocol of Profibus-DP. | |||
Digital Input | Passive dry contact | ||
Relay Output | Programmable remote/alarm relay output capacity: AC5A/250V, DC5A/30V | ||
Analog Output | 0/4~20mA or 0~5/10V | ||
DC Measurement | 2-way 0-24mA DC input measurementProgrammable alarm output | ||
Working Condition | Ambient temperature: -10~55℃Relative humidity: ≤93%Altitude: <2500mNo corrosive gas | ||
Storage | Temperature: -25~70℃Relative humidity: ≤93% | ||
Safety | Insulation | Resistance between signal/power supply/output terminal and shell: >100MΩ | |
Withstand Voltage | Between power supply and input: ≥2kVBetween power supply and output: ≥2kVBetween output and input: ≥1kV | ||
Overall Size | Front Panel | 2S□: 120×120mm, 9S□: 96×96mm, 3S□: 83×83mm | |
Hole | 2S□: 111×111mm9S□: 91×91mm3S□: 76×76mm |
This power quality monitor has extremely high price-performance ratio, and it can take the place of conventional power transmitter, measuring instrument, electricity metering device and other auxiliary equipment. It is equipped with a high-light LED or a Chinese/English LCD display, and the supported communication protocol includes Modbus-RTU and Profibus-DP. Meanwhile, our product also shows other excellent properties, such as easy installation, simple wiring, convenient maintenance, little required work, on-site programming and data inputting, etc.
Depending on these features, this digital, intelligent and state-of-the-art data collecting instrument for front-end power grid, namely PD19 series power quality monitor, is applicable for different conditions, including control system, SCADA system, energy management system, intelligent switchboard, switch cabinet, industrial automation, intelligent building, automation project in substation, power grid automation, power monitoring system in community, etc.
Model Selection
Related Names
Electrical Safety Analyzer | Power Factor Monitoring System | Power System Tool