Home Mushroom Planting Air Conditioner, 30kW-85kW Air Conditioner

Mushroom Planting Air Conditioner, 30kW-85kW Air Conditioner

This self-developed mushroom planting air conditioner is made to create an ideal environment for the cultivation of edible mushrooms in factories. The air conditioner integrates several functions, including cooling, heating, air treatment and filtering. With these features, this air conditioner can facilitate the growth of edible mushrooms, such as king trumpet mushrooms, white beech mushrooms, hen-of-the-woods, flammulina filiformis, funcia di basilicu, agaricus bisporus, caterpillar fungas and wood ear.

Mushroom Planting Air Conditioner, 30kW-85kW Air Conditioner
Download Technical Parameters

Water Source Unit

Model Z30GR Z40GR Z55GR Z75GR Z85GR
Cooling Cooling capacity kW 32 41 57 75 85
Input Power kW 7.9 10.2 15.9 18.2 18.9
Running current A 15.0 19.4 30.3 34.6 36
Heating Heating capacity kW 31 39 60 71 80
Input Power kW 10 13 19.7 22.1 23.3
Running current A 18.8 24.4 37 41.6 43.8
Start mode Directly start
Adjustment ability 0-50-100%
Refrigerant R407c/R22
Refrigerant charge kg 2.5*2 3.2*2 6.5*2 7.5*2 7.5*2
Refrigerant control device TXV
Compressor Type Hermetic scroll compressor
Qty 2 2 2 2 2
Power supply 380V/3N/50HZ
Groundwater flow m3/h 3.30 4.22 6.10 7.73 8.76
Fan Air Flow m3/h 6000 8000 12000 15000 15000
Power kW 1.5 2.2 4 5.5 5.5
ESP Pa 200 250 350 400 400
Application area   m2 200 250 350 450 550
Dimension L mm 2080 2080 2400 2400 2400
W mm 1180 1180 1410 1410 1410
H mm 2050 2050 2200 2200 2200
Air outlet A mm 500 500 630 630 630
B mm 500 500 630 630 630
Return air C mm 510 510 740 740 740
D mm 810 810 1110 1110 1110
Fresh air E mm 210 510 740 740 740
F mm 810 810 1110 1110 1110
weight kg 620 660 910 950 980
Note : Cooling: Well water in/out temperature 18/29℃
Heating: Well water in/out temperature 15℃/--

Air Cooled Unit

Model Z30FR Z40FR Z55FR Z75FR Z85FR
Cooling Cooling capacity kW 26 34 47 62 70
Input Power kW 10.1 13.1 17 20.8 23.4
Running current A 19.1 24.8 32.2 39.5 44.5
Heating Heating capacity kW 24 29 40 55 62
Input Power kW 9.9 12.9 16.8 20.4 23.2
Running current A 18.6 24.2 31.5 38.3 4.7
Start mode Directly start
Adjustment ability 0-50-100%
Refrigerant R407c/R22
Refrigerant charge kg 8 10 14 18 22
Refrigerant control device TXV
Compressor Type Hermetic scroll compressor
Qty 2 2 2 2 2
Power supply 380V/3N/50HZ
Groundwater flow m3/h 10 20 20.00 20 20
Fan Air Flow m3/h 6000 8000 12000 15000 15000
Power kW 1.5 2.2 3 4 4
ESP Pa 200 250 300 350 350
Application area   m2 150 220 300 450 550
Dimension L mm 2086 2086 2440 2640 2640
W mm 1170 1170 1370 1370 1370
H mm 2150 2150 2150 2384 2384
Air outlet A mm 500 500 630 630 630
B mm 500 500 630 630 630
Return air C mm 735 735 910 1030 1030
D mm 1110 1110 1110 1310 1310
Fresh air E mm 358 358 460 460 460
F mm 1110 1110 1110 1110 1110
weight kg 540 540 790 830 980
Note : Cooling: Ambient temperature DB 35 ℃,indoor temperature 21℃
Heating: Ambient temperature DB 7 ℃,WB 6 ℃
Features Ensure a clean growth environment for mushrooms;
Able to eliminate contaminated spores;
Equipped with evaporator coil with strong cooling capacity that can bring down indoor temperatures quickly;
Equipped with centrifugal fan that can move large air volume and develop high pressure. The air volume is adjustable.
Equipped with high-performance airtight static pressure fan that makes up high-efficiency filter outlet, which consists of primary and secondary air filters.
Equipped with heat exchanger coils that can cool down environment with refrigerants or water. This means the air conditioner can bring down environment temperatures by moving large volume of air and utilizing water from wells, rivers, lakes, and reservoirs. Applications

Applicable for cold-temperate mushrooms, such as king trumpet mushrooms, hen-of-the-woods, caterpillar fungas

Treat air for different processes of factory mushroom cultivation, such as cultivating, collecting and packaging;
Multiple functions: cooling, heating, filtering, bringing in fresh air, returning air, moving large volume of air and developing high pressure;
Easily connected with existing air ducts to deliver fresh air;
Able to filter out almost all solids and particulates and to precisely control the composition of air, for instance, the ratio between carbon dioxide and fresh air;
Ensure optimal temperature;
Able to utilize water from natural waterbodies, which will boost cooling capacity and save energy;
In northern China, heating system can use energy provided by the regional central heating system, which makes perfect economic sense for local companies.

Applicable for cold-tolerant mushrooms, such as flammulina filiformis and funcia di basilica

Centrifugal fan can move large volume of air and develop high pressure;
Able to draw in air effectively to ensure temperatures, humidity and carbon dioxide density stay at the same level, which will improve the quality and yields of mushrooms;
Minimize risks of contaminated spores and shorten time required for mushroom maturity;

Recommended Products