Standards
The 1kV insulated aerial cable is produced in accordance with GB/T12527-2008 standard: aerial insulated cables of rated voltage up to and including 1kV. On the other hand, it also meets our enterprise standard.
Operating Conditions
1. Rated voltage U0/U: 0.6/1kV
2. Max. operating temperature of conductor for long-term application: 70℃ for PVC or PE insulated type, and 90℃ for XLPE insulated type
3. Min. ambient temperature when laying: -20℃.
4. Bending radius: If the outer diameter of cable is less than 25mm, the bending radius should be larger than 4 times of outer diameter. If the outer diameter is 25 mm or higher, the bending radius should not be less than 6 times of outer diameter.
Applications
This product is weatherproof PVC, PE or XLPE insulated aerial cable with copper core, aluminum core or aluminum alloy core, and it is applicable for overhead power lines with rated voltage of 1kV AC and below.
Model Code
JK: Aerial cable
LH: Aluminum alloy
YJ: XLPE insulation
L: Aluminum
Y: PE insulation
Model | Names | Main Usages |
JKV-0.6/1 | Cu core PVC insulated overhead cable with rated voltage of 0.6/1kV | They are used as fixed overhead cable, service drop, etc. |
JKLV-0.6/1 | Al core PVC insulated overhead cable with rated voltage of 0.6/1kV | |
JKLHV-0.6/1 | Aluminum alloy core PVC insulated overhead cable with rated voltage of 0.6/1kV | |
JKY-0.6/1 | Cu core PE insulated overhead cable with rated voltage of 0.6/1kV | |
JKLY-0.6/1 | Al core PE insulated overhead cable with rated voltage of 0.6/1kV | |
JKLHY-0.6/1 | Aluminum alloy core PE insulated overhead cable with rated voltage of 0.6/1kV | |
JKYJ-0.6/1 | Cu core XLPE insulated overhead cable with rated voltage of 0.6/1kV | |
JKLYJ-0.6/1 | Al core XLPE insulated overhead cable with rated voltage of 0.6/1kV | |
JKLHYJ-0.6/1 | Aluminum alloy core XLPE insulated overhead cable with rated voltage of 0.6/1kV |
Model | Core Number | Rated Voltage 0.6/1KV Nominal Cross Section (mm2) |
JKV, JKLV, JKLHV, JKY, JKLY | 1 | 16~240 |
JKLHY, JKYJ, JKLYJ, JKLHYJ | 2, 4 | 10~120 |
JKLV, JKLY, JKLYJ | 3 K | 10~120 |
Note: K represents load carrying neutral conductor, and its section can be selected freely to match with the main core to satisfy the requirements of power distribution project.
Nominal Cross Section of Conductor (mm2) | Conductor Resistance at 20℃ (≤Ω/km) | Min. Insulation Resistivity at Rated Operating Temperature (MΩ·km) | Cable Breaking Strength (≥N) | ||||||
Cu Core | Al Core | Aluminum Alloy Core | 70℃ | 90℃ | Hard Cu Core | Al Core | Aluminum Alloy Core | ||
Hard Cur | Soft Cu | ||||||||
10 16 25 35 50 70 95 120 150 185 240 | 1.906 1.198 0.749 0.540 0.399 0.276 0.199 0.158 0.128 0.1021 0.0777 | 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 - - - | 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 | 3.574 2.217 1.393 1.007 0.744 0.514 0.371 0.294 0.239 0.190 0.145 | 0.0067 0.0065 0.0054 0.0054 0.0046 0.0040 0.0039 0.0035 0.0035 0.0035 0.0034 | 0.67 0.65 0.54 0.54 0.40 0.40 0.39 0.35 0.35 0.35 0.34 | 3471 5486 8465 11731 16502 23461 31759 39911 49505 61846 79823 | 1650 2517 3762 5177 7011 10354 137207 17339 21033 26732 34679 | 2514 4022 6284 8800 12569 17596 23880 30164 37706 46503 60329 |
Nominal Cross Section of Conductor (mm2) | Calculated Outer Diameter (mm) | Calculated Weight (kg/km) | |
Cu Core | Al Core | ||
10 16 25 35 50 70 95 120 150 185 240 | 6.5 8.0 9.5 11.0 12.5 14.0 16.5 18.0 20.0 22.5 25.5 | 106.0 169.0 264.0 360.0 518.0 734.0 998.00 1241.0 1565.0 1926.0 2485.0 | 94.0 143.0 197.0 270.0 337.0 443.0 606.0 730.0 909.0 1127.0 1459.0 |
Test Method
1. Electrical property: GB3048-1994
2. Mechanical property: GB/T4909-1985
3. Mechanical and physical properties: GB2951
Requirements for Delivery
The delivery length is negotiable, and the metering error of length should be no more than 0.5%.
Related Names