12 Ton Ladle Refining Furnace
Specifications of 12 Ton Ladle Refining Furnace
No. | Item | Unit | Data | Remark |
| |
1 | Ladle | Rated Capacity | t | 12 |
|
|
Diameter of a Molten Pool | mm | φ 1460 | 12t Molten Steel |
| ||
Height of Free Space | mm | 450 | 12t Molten Steel |
| ||
2 | Ladle Car | Walking Speed | m/min | 2-20 |
|
|
Driving Mode |
| Mechanical | Frequency Control |
| ||
3 | Electrode Lifting Unit | Electrode Diameter | mm | Φ 250 | High Power Graphite Electrode |
|
Electrode Pitch Circle Diameter | mm | Φ 460 |
|
| ||
Maximum Stroke of the Electrode Movements | mm | 1700 |
|
| ||
Automatic Lifting Speed | m/min | 4/3 |
|
| ||
Manual Lifting Speed | m/min | 5/4 |
|
| ||
Heating Rate of Molten Steel | °C /min | ≥ 3.5 |
|
| ||
4 | Furnace Lid | Lifting Stroke | mm | 300 |
|
|
5 | Hydraulic System | Working Temperature | MP a | 12 |
|
|
Working Medium |
| Water, Ethylene Glycol |
|
| ||
6 | Short Web Structure | Impedance | m Ω | ≤ 2..5 |
|
|
Unbalance Factor in a 3-phase System | % | ≤ 5 |
|
| ||
7 | Argon Gas | Working Pressure | MPa | 0.2 ~ 0.8 | 0.8Mpa (High Pressure) |
|
Consumption | NL/min | 20 ~ 100 | Adjustable |
| ||
8 | Cooling Water System | Working Temperature | Mpa | 0.3 |
|
|
Water Inflow Temperature | °C | ≤ 35 |
|
| ||
Water Return Temperature | °C | ≤ 55 |
|
| ||
Cooling Water Consumption | m3/h | 70 |
|
| ||
9 | Transformer | Rated Capacity | kVA | 2500 | Overcapacity of 20% is permitted Per Hour |
|
Primary Voltage | kV | 35 |
|
| ||
Secondary Voltage | V | 180-120 | 5 Grade(No-load Power-driven) |
| ||
Secondary Current | A | 8020 |
|
| ||
Cooling Method |
|
| OFWF |
| ||
11 | Power Supply System | High-voltage Power Supply | kV | 35 |
|
|
Low-voltage Power Supply | V | AC380 AC220 DC24 |
|
| ||
Installed Capacity of Low-voltage Equipment | kW | ~80 |
|
|