Induction Furnace
The induction furnace iscomposed of following 7 parts, furnace body, water-cooled cable, power supplyunit, water-cooling device, tilting device, water temperature and pressurealarm and leakage alarm. And the entire set of the equipment has 2 furnacebodies alternately used for maintenance and smelting purposes. And this productconducts induction heating by using SCR AC-DC-AC power supply. It has beenutilized to refine ferrous metals as well as to smelt other nonferrous metals,like copper, aluminum, etc.
Main Technical Parameters of Induction Furnace
Name | Unit | GW - 8-4000/0.5J |
Total Power | KW | 4000 |
Supply Voltage | V | 950 |
Supply Frequency | Hz | 50 |
Power Phase | Φ | 6 |
Rated Power | Kw | 4000 |
Working Voltage | V | 3200 ~ 3400 |
Rated Frequency | Hz | 500 |
Induction Furnace Phase | Φ | Single |
Rated Capacity | t | 8 |
Working Temperature | 1600 | |
Melting Rate (Steel) | t/h | 6.5 ~ 7.5 |
Power Consumption | Kwh/t | 550~590 |
Cooling Water Pressure | Mpa | 0.2 ~ 0.3 |
Water Consumption (Per Furnace) | t/h | 70 |
Size of the Furnace Body (L× W ×H) | mm | 4050 × 3800 × 3200 |
Weight of Furnace Body (not including lining ) | Kg | 18000 |