1. Product Overview
a. Our GW23A-126/145/252Ⅱ/363/550 series of high voltage disconnector is applicable to the switching of high voltage lines and the isolation of busbar or electrical equipment, such as circuit breaker, from high voltage lines.
b. The GW23A high voltage disconnector includes three monopoles and each monopole has a double-column structure.
c. The isolation switch is divided into two parts: moving side and static side. The moving side mainly consists of the base, post insulator, rotating insulator, and main switch. The post insulator and rotating insulator are mounted on the base, and the main switch is mounted on top of the insulators. The static side is composed of the base, post insulator, and main switch static contact. The post insulator is mounted on the base and the static contact is mounted on the post insulator.
The main switch has a single are folding structure. When opening, it is pulled down and a clearly noticeable horizontal insulation fracture is formed with the static contact in the horizontal direction.
d. Our GW23A high voltage disconnector can be made to have a "double static contact" form, namely, two main switches share a static contact, which can greatly reduce floor space.
e. The isolation switch can be equipped with a JW7 grounding switch and a mechanical interlocking device is set between the two.
f. The main switch and grounding switch of GW23A-126 and GW23A-145 high voltage disconnectors are equipped with electric operating mechanisms. Manual ones can be adopted according to the customer requirements. The main switch of GW23A-252 is equipped with an electric mechanism and the grounding switch is with manual one which can be replaced by an electric one. GW23A-363 and GW23A-550 are equipped with electric mechanisms.
g. Three-pole mechanical or electrical linkage can be achieved through the connecting rods between the poles.
2. Product Classification
a. Divided by voltage level: 126 kV, 145 kV, 252 kV, 363 kV, 550 kV;
b. Divided by current level: 1600A,2000A, 2500A, 3150A,4000A,5000A;
c. Divided by combination and grounding switch attached:
Single static contact: Not grounded, moving side grounded, static side grounded, double grounded
Dual static contact: Not grounded, single moving side grounded, static side grounded, one moving contact and static contact grounded, dual moving side grounded, triple grounded
Model | GW23A-126 | GW23A-145 | GW23A-252 Ⅱ | ||||||||||||
Rated voltage kV | 126 | 145 | 252 | ||||||||||||
Rated current A | 1600 | 20000 | 2500 | 3150 | 1600 | 2000 | 2500 | 3150 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000 | |
Rated peak withstand current kA | Disconnector | 100, 125 | 100, 125 | 100, 125, 160 | |||||||||||
Earthing switch | 100, 125 | 100, 125 | 100, 125, 160 | ||||||||||||
Rated short-time withstand current and rated short-circuit duration kA s | Disconnector | 40, 4 50, 3 | 40, 4 50, 3 | 50, 3 63, 3 | |||||||||||
Earthing switch | 40, 4 50, 3 | 40, 4 50, 3 | 50, 3 63, 3 | ||||||||||||
Rated 1min power frequency withstand voltage (rms) kV | To earth | 230/260* | 285/325* | 460/552** | |||||||||||
Between fractures | 300/340* | 330/375* | 605/726** | ||||||||||||
Rated lightning impulse withstand voltage (peak) kV | To earth | 550/625* | 660/860* | 1050/1260** | |||||||||||
Between fractures | 650/740* | 760/860* | 1050/1500** | ||||||||||||
Rated switching impulse withstand voltage (peak) kV | To earth | - | - | - | |||||||||||
Between fractures | - | - | - | ||||||||||||
Opening and closing bus switching current | Breaking current A | 2500 | 2500 | 2500 | |||||||||||
Switching voltage V | 427 | 427 | 427 | ||||||||||||
Breaking times | 100 | 100 | 100 | ||||||||||||
Capacitive current opened and closed (phase voltage) A | 1, 2 | ||||||||||||||
Inductor current opened and closed (phase voltage) A | 0.5, 1 | ||||||||||||||
Radio interference level | ≤500μV | ||||||||||||||
Mechanical life | 3000 times | ||||||||||||||
Rated terminal static mechanical load N | Horizontal longitudinal | 1250 | 1500 | 2000, 1500 | |||||||||||
Horizontal transverse | 750 | 1000 | 1500, 1000 | ||||||||||||
Vertical | 1000 | 1250 | 1250 |
4. Service and Installation Conditions
Ambient temperature: -50℃~ 50℃;
Altitude:≤ 2000m for GW23A-252, ≤ 3000m for GW23A-363
Wind pressure: ≤ 700Pa;
Seismic intensity: ≤ Mercalli IX;
Ice thickness: ≤ 20 mm;
Pollution class: class III and IV;
The installation site should have noinflammable, explosive, corrosive materials or violent vibration.